PRODUCTS
SPECIFICATION
|
|
MODEL
|
|
Hi-G-500-1
|
Hi-G-1000-1
|
Hi-G-1500-1
|
Hi-G-2000-1
|
|
CAPACITY |
|
500VA/300W
|
1000VA/ 600W
|
1500VA/ 900W
|
2000VA / 1200W
|
|
INPUT |
Phase
|
Single
|
|
Voltage
|
220 / 230 / 240VAC
|
|
Voltage Range
|
170-280VAC ( Narrow
Range )
|
|
|
90-280VAC (Wide
Range)
|
|
OUTPUT |
Phase
|
Single
|
|
Voltage
|
220VAC
|
|
Voltage Regulation(Batt.
Mode)
|
+10% ~ 18%
|
|
Frequency
|
50Hz or 60Hz
|
|
Frequency Regulation
(Batt. Mode)
|
± 0.1 Hz
|
|
Output Waveform
(Batt. Mode)
|
Modified Sinewave
|
|
POWER FACTOR |
P.F.
|
0.6
|
|
BATTERY |
Charger Current
|
10 Amp±1Amp |
8 Amp±1Amp |
6Amp±1Amp |
|
Floating Voltage
|
12.7V ±0.2V |
24.5V±0.2V |
12.7V± 0.2V |
24.5V±0.2V |
|
Overcharge Protection
|
14.5V± 0.3V charger stops and fault |
29±0.6V charger stops and fault |
14.5±0.3V charger stops and fault |
29V ± 0.6V charger stops and fault |
|
TRANSFER TIME |
Typical
|
8ms
|
|
EFFICIENCY |
AC to AC
|
>95%
|
|
DC to AC
|
>80%
|
|
INDICATOR |
AC Mode
|
Green LED lighting
|
|
Battery Mode
|
Yellow LED lighting
|
|
Battery Charging
Mode
|
Green LED flashing
every 2 seconds
|
|
Overload
|
Red LED flashing
every 0.5 second
|
|
Fault
|
Red LED lighting
|
|
AUDIBLE ALARM |
Low Battery at Battery
Mode
|
Sounding every 2
seconds
|
|
Overload
|
Sounding every 0.5
second
|
|
Fault
|
Continously sounding
|
|
PROTECTION |
Full Protection
|
Deep Discharge,
Overcharge, and Overload protection
|
|
PHYSICAL |
Dimension (DxWxH)
mm
|
224 X 255 X 80
|
|
Net Weight (kgs)
|
1.7 for 500VA /
300W
|
|
ENVIRONMENT |
Operating Environment
|
0~40 Degrees Centigrade,
0~90% relative humidity (non-condensing)
|
|
Noise Level
|
Less than 45dB
|